Description
The Panther product range combines speed and performance of phased-array ultrasound technology in a compact format. Targeted towards integrators for inline inspections and laboratories for R&D, Panther products offer a flexible and scalable solution for generic and custom NDT.
REAL-TIME TOTAL FOCUSING METHOD (TFM) FOR HIGH SPEED INSPECTION
Recognized amongst the highest-resolution PAUT techniques, TFM is natively implemented on Panther. Combined with unparalleled data throughput, Panther offers faster imaging of larger inspection zones for easier evaluation.
COMPACT, RUGGED & SCALABLE
From 32:128 to 2048:2048 configurations, Panther compact units are scalable for automated inspection. With up to 16 units used in parallel, Panther offers a substantial increase in inspection speed.
• Unlimited number of probes
• Unlimited number of groups
• Up 13k+ focal laws
Panther is IP54. Its casing has external fans for optimized heat dissipation with no air intake.
FASTEST DATA THROUGHPUT
Uniquely equipped with a 320MB/s high-speed link, Panther offers the fastest data throughput of the market.
ADVANCED PHASED-ARRAY MODES
The CIVA-based Acquire monitoring software and its extensive SDK allow managing fast industrial modes and advanced laboratory configurations:
• 3D CAD configuration and rendering
• LINEAR, MATRIX, DLA, DMA, DAISY, ANNULAR, SECTORIAL probes
• PE, TOFD, PAUT, FMC, PWI, TFM Imaging techniques
• FAST modes
• SAUL modes
• Adaptive TFM modes
• 3D real-time imaging
Specification
GENERAL
L x W x H:
300mm x 220mm x 155mm
Weight:
6kg
Operating temperature range:
from -10°C to 50°C | 14°F to 120°F
IP54
Storage temperature range:
-10°C to 60°C | 14°F to 140°F
Power supply:
240V50Hz – 110V/60Hz
PHASED-ARRAY
Linear scanning, sectorial scanning, parallel shooting, ultrafast mixed modes
Linear, Matrix, DLA and DMA, Annular and Daisy probes
Maximum active aperture:
2048 channels (with 16 Panther units)
Unlimited probe number | No group limitation | Up to 13100 focal laws
Delay-law computation for standard and parametric components (plates, pipes, TKY junctions, nozzle, elbows, turbine blades…) as well as 2D and 3D CAD
Focusing mode:
true depth, sound path, projection
REAL-TIME TFM, FMC, PWI
Reconstruction channels:
up to 128
Max number of pixels for the reconstructed image:
more than 1 Million
Max refresh rate:
up to 500fps (depends on the pixel numbers)
Multiple Sound paths:
direct (L or S), indirect and converted modes, Modes superposition
PULSERS
128 phased-array channels*:
Bipolar square pulse, width: 30ns to 2000ns
Voltage amplitude: max 180V with 1V step
Max. PRF: up to 40kHz
RECEIVERS
128 phased-array channels*:
Input impedance: 50 Ω
Gain: up to 120dB (0.1dB step)
Frequency range: 0.4 to 20MHz
Cross-talk between two channels < 50 dB
Max. input signal: 1.8Vpp
Ultralow noise amplifier
DIGITIZER
Digitizing and real-time summation on 128 channels
Resolution:
14bit
Dynamic:
16bit
IIR filters
Max. sampling frequency:
125 MHz
Rectified, RF, envelope
Digitizing depth:
up to 16k points
Max delay:
1.6 ms
Max A-scan range:
65k points
ACQUISITION
A-Scan/Peak data recording
800% amplitude range
High speed FMC recording (320 MB/s)
Inspection data file size:
hard drive limitation
Acquisition trigger on time, event, encoder
Data transfer through USB3
WIZARDS
CAD overlay and 3D view
Amplitude balancing
Real-time phased array calculator
Probe design | Weld geometry design
Wedge calibration (angle, height)
Amplitude calibration (TCG, DAC)
Part geometry with parametric shapes (plates, cylinders, Butt Welds, T K & Y welds, elbow, blade, nozzles,…), 2D and 3D CAD
ANALYSIS
Powerful CIVA Analysis© and EnlightTM software with analysis and reporting tools
Amplitude range:
up to 800%
A-Scan, B-Scan, C-Scan, D-Scan, Echodynamic, Top – Side – Front views
CAD part geometry:
plate, cylinder, T or Y section, nozzle